35001AL-1-9028/1000P/L0 – Gas Detector Ex-Proof
35001AL-1-9028/1000P/L0 – Gas Detector Ex-Proof
35001AL Series
Brand : RC Systems, Inc
- 3500AL 3 wire gas detector.
- VOC 0-40ppm to 0-1000ppm
-
Description
Enclosure Type - AL-Aluminum
Model - Standard 3 wire model
Output - 1-Standard 4 to 20 mA output and 100234 MODBUS RTU w/ 3 relays
Sensor Range - 1000P-0 to 1000ppm
Splash Guard - L0-Local Mount no Splash GuardGeneral Specification
Power Supply Power Input 10-30VDC at < 6.5 watts with relay board (all relay energized)
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bar graph and engineering units display
Channel One Input Electrochemical toxic and oxygen sensors / 4-20ma current input
Channel Two Input Catalytic Bead, Infrared and Photoionization sensor / 4-20mA current input
Standard Output Dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Outputs Dual isolated 4-20mA current source. Max loop Resistance is 650 ohms with nominal 24VDC; (form C , rated 5 amp at 30 VDC or 240 ~VAC RESISTIVE) MODBUS slave ports; 3x programmable alarm relays with 5A capability
Temp Electronics -40°C to +60°C
Housing Aluminum with epoxy paint standard; Optional #316 stainless steel, Optional Ul94 Poly Black Plastic Enclosure
Dimensions (Aluminum) Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
(Poly) Width 5” (127 mm), Height 7” (178 mm), Depth 4” (101 mm) Shipping weight 3 pounds (2 kg)
CSA Approvals Cast Aluminum Enclosure:
Explosion-Proof Cl 1 Div 1 Gr ABCD with 10-0247 (includes sinter)
Non-Incendive Cl 1 Div 2 Gr ABCD with 10-0247 or 10-0247IS
UL94 Poly Black Plastic Enclosure:
Non-Incendive Cl 1 Div 2 Gr ABCD
Read More
FEATURES HIGHLIGHT
- CSA Certified for Class I, Div 1 Locations
- Graphic LCD display shows values, units, trend graph, alarm levels
- Backlit display for better visibility in low light conditions
- LED indication of alarm status
- Dual smart sensor capable
- Supports both local and remote sensors for easy installation
- Non-intrusive, prompted calibration with programmable cal-gas
- Power-up and post-calibration delays eliminate false alarms
- Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
- Aluminum “AL” XP model wtih Dual Sensor
- Auto-recognition of Smart Sensors uploads calibration data and more
- Real-time clock and calendar logs alarms, calibration and power-up events
- Security mode allows locking of critical parameters
- Fault supervision circuitry detects failed sensor and transmits warning
- Setup in hazardous area requires only simple magnetic wand
- Optional HART board available
Latest Reviews
-
Additional information
Choose Pressure Range 2000-100PA, 2000-500 PA, 2000-750 PA, 2000-1000 PA, 2000-1500 PA
-
Brands (1)
RC SYSTEMS
RC Systems, Inc. has representatives located internationally and throughout the United States to assist you with selecting the right gas detectors and wireless gas monitoring systems for your application. We also provide 24/7 technical service support from local experts to provide you with fast answers for all your gas detection questions.
Finding the right wireless gas monitor isn’t always easy. Reliability is a top priority, but with so many products available, how do you know which one is right for your specific application? Once your gas detector is installed, you also want to make sure you have the right support.
RC Systems, Inc. has been in business since 1979 and has a wealth of experience designing and manufacturing gas detectors. We understand the importance of having a reliable monitoring system and offer effective gas detection solutions for various gases and applications. Whether you need a gas detector, or a custom product designed for detecting a specific gas or substance, we can help you find the right solution.
Contact us today to discuss your critical alarm control requirements and learn more about our gas detectors and other gas monitoring solutions.